What it is

Where there is room to consume: 84,648 MW available with no export constraint (CAP_DEMANDA_NOCEP) at 282 of the 937 transmission nodes, nearly twelve times what the whole distribution grid offers. This is the layer that matters for large loads — data centres, industrial electrification, electrolysers — and the split is strongly territorial: Murcia 8,284 MW, Ourense 7,741, Burgos 5,690, Sevilla 4,512 and Badajoz 4,193. Single operator, REE (R1-000), 787 substations, 220 kV (566), 400 kV (218) and 66 kV (129) in the island systems. POSICIONES_LIBRES counts physical bays available, not MW: 1,399 free against 85 occupied — the opposite of generation, where the bay is the bottleneck — and with no bay there is no connection however many MW are listed. ⚠ The figure splits by power export constraint: CAP_DEMANDA_CEP_CAD1 (52,899 MW at 264 nodes) and CAP_DEMANDA_NOCEP (84,648 MW) do not add up; they are two readings of the same node. CAP_DEMANDA_CEP_CAD2 comes zero across all 937 rows, and that is how CNMC publishes it. ⚠ The two storage columns, CAP_ALM_CEP and CAP_ALM_NOCEP, are identical row by row: not two independent figures. ⚠ GESTOR_RED and DESCRIPCION hold a single distinct value across the layer. ⚠ CAP_ADMITIDA_NO_EVALUADA is 24,044 MW of admitted, unresolved applications. Extract PERIODO = 072026. CNMC overwrites monthly and publishes no archive, so each extract ships as its own dataset with the month in the identifier; June (062026) remains available without a suffix. ⚠ CNMC warns the figures are indicative and, because nodes influence one another, not directly additive.

According to the publishing agency

Official text, in Spanish, exactly as the upstream service publishes it:

Información de acceso y conexión a las redes En cumplimiento de la Circular informativa 6/2025, de la CNMC los gestores de red envían de forma sistemática información relevante sobre acceso y conexión a las redes de transporte y distribución de electricidad. Tras recopilar y tratar los datos recibidos, la CNMC publica mensualmente la información sobre capacidad de acceso en los mapas correspondientes. Dichas capacidades deben considerarse como informativas y, debido a la influencia de unos nudos sobre otros, sus valores no pueden computarse como directamente sumables. Cabe señalar que las eventuales solicitudes de permisos de acceso y conexión deben dirigirse al gestor de red correspondiente, tal como se indica en la legislación específica sobre acceso y conexión a las redes de electricidad.

At a glance

IDes_energia_capacidad_demanda_transporte_072026
Records937
Size0.1 MB
GeometryPOINT
CRSEPSG:4326
Versionv/2026-08
Sourcecnmc
Upstream layercnmc:Demanda_en_Transporte_v2/11
LicenceCC-BY-SA-4.0

Extent: -17.915957, 27.764805 → 4.257851, 43.693308

Download

curl -H "x-api-key: $GEOVIS_API_KEY" \
https://datos.geovis.es/v1/data/datasets/es_energia_capacidad_demanda_transporte_072026/download

sha256 of this version:

a117c09f2d9c8895fb3618c741311140ff8de7ac17ba882ce83a49a1c7b057e9

Query it without downloading it

import duckdb
con = duckdb.connect(); con.execute("INSTALL spatial; LOAD spatial; INSTALL httpfs; LOAD httpfs;")
con.execute("SELECT count(*) FROM read_parquet('<url-firmada>')").fetchone()

Columns

Column names are kept exactly as the agency publishes them. They are not translated: renaming them would break traceability against the official source.

The literals below are the ones present in the data: they work as-is in a WHERE. Only columns with few distinct values are enumerated; for the rest, the count is given.

ColumnTypeFilledDistinctValues
GESTOR_REDVARCHAR100 %1R1-000
DESCRIPCIONVARCHAR100 %1[REE] RED ELÉCTRICA DE ESP
PROVINCIAVARCHAR100 %50
MUNICIPIOVARCHAR100 %565
SUBESTACIONVARCHAR100 %787
NIVEL_TENSIONINTEGER100 %5220 · 400 · 66 · 132 · 30
CAP_DEMANDA_CEP_CAD1INTEGER100 %177Range: 0 → 875
CAP_DEMANDA_CEP_CAD2INTEGER100 %10
CAP_DEMANDA_NOCEPINTEGER100 %204Range: 0 → 1229
CAP_ALM_CEPINTEGER100 %245Range: 0 → 1248
CAP_ALM_NOCEPINTEGER100 %245Range: 0 → 1248
CAP_COMPROMETIDAINTEGER100 %20 · 1
CAP_OCUPADADOUBLE100 %169Range: 0.0 → 691.0
CAP_ADMITIDA_NO_EVALUADADOUBLE100 %66Range: 0.0 → 2970.0
CAP_ALM_OCUPADADOUBLE100 %143Range: 0.0 → 1536.45
CAP_ALM_ADMITIDA_NO_EVALUADADOUBLE100 %99Range: 0.0 → 700.97
POSICIONES_OCUPADASINTEGER100 %60 · 1 · 2 · 4 · 3 · 6
POSICIONES_LIBRESINTEGER100 %110 · 2 · 3 · 1 · 4 · 5 · 6 · 8
PERIODOVARCHAR100 %1072026
prov_codeVARCHAR100 %50
prov_nameVARCHAR100 %50
prov_aproxBOOLEAN100 %1false
_fuenteVARCHAR100 %1cnmc
_fecha_capturaDATE100 %12026-08-29
_fecha_edicionDATE100 %12026-08-29
_licenciaVARCHAR100 %1CC-BY-SA-4.0
_atribucionVARCHAR100 %1Origen de los datos: Comis
bboxSTRUCT(xmin DOUBLE, ymin DOUBLE, xmax DOUBLE, ymax DOUBLE)100 %—
geometryGEOMETRY(‘EPSG:4326’)100 %—